Over the years, the demand for paint testing at high pressure and temperature in combination with corrosive gases increases. In various standards and specifications such as ISO 15741, EN 10289, EN 10290, ARAMCO 09-SAMSS-067 APCS 27, NACE TM0185 or various Shell DEP’s measurement results of autoclave tests are required.
Our autoclaves can achieve pressures up to 410 bar and up to 350 °C. In addition gases can be added as, for example, CO2 , H2S, CH4 and SO4 and all kinds of test liquids are introduced into desired concentrations. The duration of test ranges from 24 hours up to a month or longer.